Prism-IPX Systems and TPL Systems have Partnered to Develop the Industry’s First, Fully Integrated, P25 Activated Siren Controller, the MPSC-1™
Why P25?
Reliability
Systems are built with a high degree of redundancy, ensuring message reliability.
Professionally Monitored and Maintained
Given the critical nature of Public Safety communications, any system anomaly has to be addressed quickly to ensure minimum service interruption.
Secure Communications
Provides secure communications to protect against malicious intervention.
Superior RF Coverage
Administrators are continuously investing in improved RF coverage and services
Why Consider the MPSC-1 Controller?
Supports Multiple Systems
In addition to P25, the MPSC-1TM supports legacy analog environments thereby allowing operation on a legacy system with a seamless transition to P25.
Fully Integrated for High Reliability
One PCB supports multiple systems.
Ease of P25 Integration
Due to the MPSC-1TM software design, it will have no impact on P25 System resources.
Status Reporting
The MPSC-1TM supports Internet and 3/4G LTE interfaces, which can be used for alternative activation control and /or operational status reporting.
Upgradeable
Its hardware modularity and Software Designed Radio architecture allow for ease of upgrade or redeployment.
Specifications
Electrical
DC Input Voltage Range: 9 – 48V Nominal
4 Outputs Rugged Contact Relays:
– AC: 16A @ 250VAC
– DC: 8A @ 24VDC
4 Inputs Dry Contacts :
– External Button for Siren Activation
– Power Supply Alarm
– User Input Source 1
– User Input Source 2
Board Connectors: RS485 , Ethernet RJ45, USB C, Antennas.
Operating Temperature: -22 to +158 Fahrenheit
Radio Protocols
P25 Module: Conventional/ Trunked Phase I & II
Frequency Range: VHF/ UHF/ 763 – 776 MHz / 851 – 870 MHz
Sensitivity: -119dBm Typical
Rejection: 70dB
Selectivity: >60dB
Spurious: >70dB
Antenna Impedance: 50 Ohms
VHF/UHF Module: 2Tone/DTMF/POCSAG
Frequency Range: 136 – 174 MHz / 434 – 470 MHz
Sensitivity: -119dBm Typical
Channel Spacing: 6,25kHz/12,5kHz/25kHz
Baud Rate: 512, 1200 or 2400
Antenna Impedance: 50 Ohms
3G/4G LTE Module:
Category: Cat-1
Frequency Bands: B2, B4, B5, B12, B13, B14, B25, B26, B66, B71
Data Speed: Peak Download Rate 10Mbps
Peak Upload Rate 5Mbps
Planned Carrier: AT&T, Sprint, T-Mobile, Verizon
Regulatory : FCC, GCF, IC, PTCRB
Mild Steel Box
Dimensions: H 14 in x W 12 in x D 6 in
Weight: Complete Box Wired 19 lbs. Board Only 2 lbs.
Door: Front Face, 120° Opening, Padlockable Quarter Turn Latch
Standards: UL 864, UL 508A Type 3R, 4, 12 and 13
CSA Type 3R, 4, 12 and 13
Complies with NEMA Type 3R, 4, 12 and 13
IEC 60529, IP66
Cable gland with N connectors on the bottom of the cabinet for antennas